small water to water heat pump R410A

Small water to water heat pump R410A

Model AC+GSHP 4.5BAF - 110BAF
Brand AC+
Unit set
Min order 1
Supply ability 100 sets per month
Payment T/T
Port Chinese port
Certification CE
Place China
Packaging Export Standard
Send Inquiry

Small water to water heat pump R410A has blew features

FEATURES:

STRUCTURE
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.

HERMETIC COMPRESSORS
Single phase type (mod. 4.5÷6.5) and 3-phase (mod.10÷110) scroll type compressors, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Mod. 10 and 12 are available with single phase compressors.

EVAPORATOR
High efficiency plate heat exchanger, factory insulated with flexible close cell material.
CONDENSER
High efficiency tube in tube heat exchanger, factory insulated with flexible close cell material.

REFRIGERANT CIRCUIT
Copper tube connection with charge valves, filter, thermostatic expansion valve (capillary for mod. 4.5÷25 for standard conditions), gas-liquid separator, high pressure switch and low pressure switch.
The heat pump units are complete also with 4-way valve and one way valve.

HYDRAULIC CIRCUIT 
Built with user side and source side water inlet/outlet connectors, water discharge connectors, air vent valve,  for mod.8÷38 the user side is complete also with expansion vessel, water pump and water flow switch.

ELECTRIC PANEL
Consists of:
Compressor contactor, 
Compressor protection breaker, 
User side water pump contactor (for mod.4.5÷38),
User side water pump breaker (for mod.4.5÷38),
Microprocessor with function display.

OPTIONAL 
Sight glass which must be installed in factory,
Source side water flow switch,
Source side water pump,
Anti-vibration rubber,
Metallic filter for the water circuit.
Desuperheater as optional

NOMENCLATURE 

TECHNICAL DATA for Underground water

Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 18ºC/29ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 15ºC/8ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.


TECHNICAL DATA for Soil source



Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 25ºC/30ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 8ºC/4ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.

TECHNICAL DATA for waste water

Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 30ºC/35ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 20ºC/15ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.

TECHNICAL DATA for Underground water

Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 18ºC/29ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 15ºC/8ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.

TECHNICAL DATA for Soil source

Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 25ºC/30ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 8ºC/4ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field

TECHNICAL DATA for waste water


Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 30ºC/35ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 20ºC/15ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.

OVERALL DIMENSIONS


Mod. AC+ GSHP4.5 ÷ 35BAF 

NO.NameNO.NameNO.Name
1.

Heat recovery inlet 1

5.

Communication line

11.

Electrical box

2.

Heat recovery outlet 1

6.

Power cableφ35

9.

User side inlet

3.

Source side inlet

7.

Unit installation hole 4-φ13

10.

User side outlet

4.

Temp. sensor hole

8.

Source side outlet



Note: 
1.1 means there is heat recovery inside, otherwise, no this.
2. There should be 500mm at least around the unit for service. 

Model

Code and size

A

B

C

D

E

F

G

H

I

J

K

L

M

N

GSHP4.5BAF1U GSHP6.5BAF1U

580

720

192

375

405

485

110

530

334

154

93

250

--

--

GSHP10BAF(H)1/5U GSHP12BAF(H)1/5U

770

972

289

500

530

100

676

720

484

164

100

466

627

172

GSHP16BAF(H)5U GSHP20BAF(H)5U GSHP25BAF(H)5U

770

972

324

535

565

100

680

720

484

164

100

466

627

172

GSHP30BAF(H)5U GSHP38BAF(H)5U

825

972

359

580

610

115

676

775

538

164

130

466

657

172



Mod. GSHP45 ÷ 110BAF

No

Name

No

Name

No

Name

1.

Heat recovery inlet 1

6.

Unit installation hole 4-φ13

11.

Power cableφ35

2.

Heat recovery outlet 1

7.

Source side outlet

12.

Unit lifting holeφ40

3.

User side inlet

8.

Electrical box

 

 

4.

Temp. sensor hole

9.

Source side inlet

 

 

5.

User side outlet

10.

Communication lineφ22

 


Note:  
1.1 means there is heat recovery inside, otherwise, no this.
2. There should be 500mm at least around the unit for service.



Model

Code and size

 

A

B

C

D

E

F

G

H

I

GSHP45BAF(H)5

730

850(1050)

686

200

327

836

600

910

880

GSHP50BAF(H)5 GSHP56BAF(H)5 GSHP65BAF(H)5

800

850(1050)

756

211

374

1236

800

1310

1280

GSHP75BAF(H)5 GSHP90BAF(H)5

880

850(1050)

836

231

414

1406

920

1480

1450

GSHP110BAF(H)5

880

850(1050)

836

231

414

1606

1096

1680

1650

Small water to water heat pump R410A

Model:AC+GSHP 4.5BAF ÷ 110BAF

Cooling capacity: 4.5 ÷ 106.4kW
Heating capacity: 5.22 ÷ 123.4 kW